ADAPTER TUBE ASSEMBLY--(LATE PRODUCTION)--MAINTENANCE INSTRUCTIONS (CONT).
REASSEMBLY (CONT).
5
a.
Position electric light control (14) in front cover (2)
with the stem of the electric light control protruding
through the hole toward the front, and the wires
toward the two holes where the circuit breaker and
toggle switch will be installed.
b.
If removed, solder lug terminal (15) to green wire
(11) using solder. See TM 9-254.
c.
Position lug terminal (15) over the mounting hole.
d.
Install and tighten two machine screws (16), two
washers (17), and two nuts (18) to secure the lug
terminal (15) and the electric light control (14).
6
a.
If removed, solder six terminals (19) on red jumper
wire (20), red wire (21), and three black wires (22,
23, and 24). See TM 9-254.
b.
Position red jumper wire (20), red wire (21), and
three black wires (22, 23, and 24) on the toggle
switch (25).
c.
Install and tighten six washers(26) and six screws
(27).