5-30.
ADAPTER TUBE ASSEMBLY--(EARLY PRODUCTION)--MAINTENANCE INSTRUCTIONS (CONT).
REASSEMBLY (CONT).
11
a. If removed, solder three lug terminals (42) to the
two blue wires (14 and 43) and white wire (44).
See TM 9-254.
b. Install two blue wires (14 and 43) and white wire
(44) on toggle switch (5).
12
CAUTION
Do not allow solder to enter the
sleeves on the electrical assembly
contact (7).
NOTE
Ensure the three electrical contacts
(6) have the spring loaded portion
facing the large hole in the front
cover where the adapter tube is
installed.
a. Solder blue wire (43) to the top contact, black
wires (25 and 34) to the center contact, and two
white wires (26 and 44) to the bottom contact of
electrical assembly contact (7). See TM 9-254.
b. Position electrical assembly contact (7) on front
cover (2).
5-94