ARMY
TM 9-6650-235-13&P
MARINE CORPS
TM-08552A-13&P
5-30.
ADAPTER TUBE ASSEMBLY--(EARLY PRODUCTION)--MAINTENANCE INSTRUCTIONS (CONT).
DISASSEMBLY (CONT).
6
a.
Disconnect two blue wires (10 and 15) and one
white wire (14) from toggle switch (16).
b.
If necessary to replace wires or lug terminals,
unsolder and remove the lug terminals (17) from
the three wires (10, 14, and 15).
7
a.
Remove nut (18), washer (19), and 24-volt circuit
breaker (20).
b.
Remove nut (21), washer (22), and 115-volt circuit
breaker (23)
.
5-82
|