ARMY
TM 9-6650-235-13&P
MARINE CORPS
TM-08552A-13&P
5-28.
OPTICAL ELEMENT ERECTOR LENS CELL ASSEMBLY--MAINTENANCE INSTRUCTIONS.
This task covers:
a. Disassembly/Repair/Reassembly
INITIAL SETUP
Tools and Special Tools
Troubleshooting References
Instrument and fire control shop
equipment SC 4931-95-CL-A07
through the M3 Borescope
Socket wrench case 11584760
Equipment Condition
Materials/Parts
Lens paper (item 10, app D)
cell assembly removed from
Optical lens cleaning compound
borescope extension tube
(item 2, app D)
References
TM 9-254
DISASSEMBLY/CLEANING/REPAIR.
a.
If setscrews or optical instrument lens is damaged,
remove three setscrews (1) from lens mounting
sleeve (2).
b.
Remove optical instrument lens (3) from lens
mounting sleeve (2).
c.
Dust optical instrument lens (3) with the brush from
the socket wrench case. Clean with lens paper and
optical lens cleaning compound. See TM 9-254.
d.
Inspect for cracks, breaks, worn or missing parts.
e.
Replace authorized parts. See appendix C.
f.
If lens mounting sleeve is damaged, order optical
element erector lens cell assembly 11584718 for
replacement.
5-75
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |