![]() ARMY
TM 9-6650-235-13&P
MARINE CORPS
TM-08552A-13&P
5-21.
OPTICAL ELEMENT ERECTOR LENS CELL ASSEMBLY--MAINTENANCE INSTRUCTIONS.
This task covers:
a.
Disassembly/Cleaning/Repair
b. Reassembly
INITIAL SETUP
Tools and Special Tools
Troubleshooting References
Instrument and fire control shop
equipment SC 4931-95-CL-A07
through the M3 Borescope
Socket wrench case 11584760
Equipment Condition
Materials/Parts
Lens paper (item 10, app D)
cell assembly removed from
Optical lens cleaning compound
objective tube assembly
(item 2, app D)
References
TM 9-254
DISASSEMBLY/CLEANING/REPAIR.
a. If setscrews or optical instrument lens is
damaged, remove three setscrews (1) from lens
mounting sleeve (2).
b. Remove optical instrument lens (3) from lens
mounting sleeve (2).
c. Dust optical instrument erector lens (3) with the
brush in the socket wrench case. Clean with
lens paper and optical lens cleaning compound.
See TM 9-254.
d. Inspect for cracks, breaks, worn or missing
parts.
e. .Replace authorized parts. See appendix C.
f If lens mounting sleeve (2) is damaged, order
optical element erector lens cell assembly
11584718 for replacement.
5-61
|