#I- AIRMOTOR AGITATOR for ASME-AS
GALLON and LARGER PRESSURE
FLUID TANKS
Airmotor Agitators
#5 SMALL SIZE AIRMOTOR AGITATOR
OPERATING INSTRUCTIONS
for ASME-A3 GALLON PRESSURE
FLUID TANKS
#3 & #4 AIRMOTOR AGITATOR for CLAMPING TO OPEN TOP CONTAINERS
starting agitation, after which airmotor should be
Ball - Bearing Airmotor Agitators operate for long
adjusted to lowest practical speed to conserve air and
periods of time with very little attention. This explosion-
prevent over agitation or mixing. "V" type packing will
proof unit will keep most types of finishing materials
last indefinitely when oiled with best grade lubricant
mixed to uniform consistency. The Agitator Propellers
every 30 days.
create a continuous circulating and mixing action.
Adjustable speed control provides quick action for
CAUTION:
When using Airmotor Agitator DO NOT FILL Pressure Tank more than Three
Quarters Full. When Mounting Airmotor Agitator Unit to M-I Housing - Adjust all
set screws equally to prevent misalinement of Agitator Shaft.