TM 9-4931-710-14&P
5-8
COLLIMATION AND INSPECTION - CONTINUED
COLLIMATION OF AZIMUTH TEST FIXTURE - CONTINUED
M
If necessary, rotate azimuth test fixture (1) so infinity collimator (4) faces projector collimator (9).
N
Raise or lower projector collimator (9) to aline with infinity collimator (4). Set projector collimator objective cell (13)
to infinity.
Note
Position the projector collimator (9) so that while sighting through the infinity collimator (4), the
field of view is centered on the projector collimator (9).
O
Lock the azimuth test fixture (1) and height adjustment of projector collimator (9).
P
Using tilt adjustment (14) on the projector collimator (9) and the fine adjustment knob (15) on the azimuth scale (16),
sight through infinity collimator (4) and superimpose the two reticles.
5-26 Change 1
|