TM 9-4931-710-14&P
5-5
RETICLE CELL ASSEMBLY MAINTENANCE INSTRUCTIONS-CONTINUED
DISASSEMBLY
Remove retaining ring (1) and sealing compound from
reticle (2) and cell (3). Remove reticle (2) from cell (3).
CLEANING
REPAIR
Clean all( parts per TM 9-254.
Repair is by replacement of authorized parts as required
REASSEMBLY
Note
The etched face of the
reticle must face slotted
side of cell. Aline reticle
lines 44 to 46 degrees from
center lines of slots.
A
Install reticle (1) in cell (2) and position the reticle
to 45.
B
Apply sealing compound (Item 8, Appendix D) to
three places, securing reticle (1) to cell (2).
C
Install retaining ring (3) and apply sealing
compound to cell (2) and retaining ring (3) in two
places.
Change 1 5-15
|