PICKOFF AND ELECTRICAL CONNECTIONS
The pick-off connector is the AN dual contact type, MS3106A-10OSL-4P.  Mating connectors and two (2)
different lengths of cable (50 feet and 150 feet) are supplied with the flowmeter kit. The mating cable connector at the
flowmeter is an MS3102A-10SL-4S (See Figure 9).
1.7
END CONNECTIONS
End connections of the flowmeter kit are ground threads conforming to MS33656-8 and -16. Flow direction is
deeply etched on the respective housing.
Straightening sections are provided with transfer kit FT-AFS-4-CF with upstream and downstream sections
marked as to orientation.
1.8
FLOWMETER DIMENSIONS
FIGURE 5.