1.4
MIS-10391A SPECIFICATIONS
PARAGRAPH
ITEM
REQUIREMENTS
NO.
3.2.7.1
FLOWMETER RANGE
1/2" Meter 1.0 - 10 GPM:
1" Meter 3 - 50 GPM
3.2.7.2
FLOWMETER OUTPUT
Min. Output of 1800 Cycles
per sec under 3.2.7.1 Flow Rates
3.2.7.3
FLOW RANGE
1.0 to 50 GPM
3.2.7.4
VISCOSITY RANGE
Viscosity Range of 0.5 to 30
Centistokes (cs)
3.2.7.5
PRESSURE RANGE
10 to 2500 PSI
3.2.7.7
PRESSURE DROP
Less than 10 PSID at Maximum
Flow Rating and 30 CS
3.2.7.8
TEMPERATURE RANGE
50 - 150 Degrees Fahrenheit
WARNING
WATER IS NOT AN ACCEPTABLE FLUID FOR
USE WITH THIS FLOW TRANSFER KIT
1-21
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |