TM 9-4931-381-14&P-1
OPERATOR ASSISTED SELF TEST PROCEDURE
Table 6-3. AUTOMATIC SELF TEST FAIL CODE INDEX
Code
Corrective Action
Display
I
A
Replace processor circuit card assembly A2; refer to Remove and InstalI
Circuit Card Assembly, Volume IV, para 2-7.
B
Replace panel interface circuit card assembIy A3; refer to Remove and instalI
Circuit Card Assembly, Volume IV, para. 2-7.
Replace stimuli circuit card assembly A10; refer to Remove and Install Circuit
C
Card Assembly, Volume IV, para. 2-7.
D
Replace stimuli circuit card assembly A9; refer to Remove and Install Circuit
Card Assembly, Volume IV, para. 2-7.
Replace panel interface circuit card assembly A3; refer to Remove and InstalI
E
Circuit Card Assembly, Volume IV, para. 2-7.
F
Replace processor circuit card assembly A2; refer to Remove and InstalI Circuit
Card Assembly, Volume IV, para. 2-7.
Replace digital voltmeter circuit card assembly A4; refer to Remove and lnstalI
G
Circuit Card Assembly, Volume IV, para. 2-7.
Replace scanner circuit card assembly A7; refer to Remove and InstalI Circuit
H
Card Assembly, Volume IV, para. 2-7.
I
Replace scanner circuit card assembly A6; refer to Remove and InstalI Circuit
Card Assembly, Volume IV, para. 2-7.
Replace scanner circuit card assembly AS; refer to Remove and InstalI Circuit
J
Card Assembly, Volume IV, para. 2-7.
K
Same as fault symptom #9; refer to Fault Symptom Index, chapter 4.
Replace video data processor printed circuit board assembly A14; refer to
L
Remove and InstalI Circuit Card Assembly, Volume IV, para. 2-7.
M
Replace TRU-FCS simulator circuit card assembly A13; Refer to Remove and
Install Circuit Card Assembly, Volume IV, para. 2-7.
Figure 6-2. Operator Assisted Self-Test (Sheet 25 of 29)