TM 9-4910-736-14&P
Proceed as follows:
b.
High Voltage Pick-up Check.
(1) Set FUNCTION switch to OHM.
(2)
Connect audio generator to the hot side of the COIL PICK-UP
and to the test lead with the black boot.
(3) Set audio generator output to 100 V at 1 kHz.
(4) Using AC VTVM, measure the voltage level between point E27 and
the black booted test lead. The voltage should be 10.5 mV 10%.
(5) Disconnect the AC VTVM and the audio generator.
(6) Disconnect all leads.
3-23/(3-24 blank)
|