TM 9-4910-736-14&P
(1) Connect TEST LEAD with red boot to + terminal and the other TEST
LEAD to - terminal.
(2) Depending upon the coil under test, using the proper adapter (as
indicated below), connect the COIL PICK-UT to the high tension tower
of the coil.
Coil under test
Adapter no.
Prestolite - Autolite 115047
403BA032
P&D Mfg. VC2X
403BA032
Delco-Remy 1915992
403BA031
(3) Connect black lead attached to COIL PICK-UP to chassis of vehicle
or to another good ground.
(4)
Set FUNCTION switch to COIL.
WARNING
When PUSH TO TEST switch is depressed, HIGH VOLTAGE is
present across all leads and coil under test. DO NOT
touch leads or coil under test when PUSH TO TEST switch
is depressed.
(5) Observe WARNING and depress PUSH TO TEST switch. While holding
PUSH TO TEST switch depressed, adjust COIL CURRENT control clockwise
until meter indicates 20 to 25 KV on the black scale. Check that
COIL FLASHOVER indicator does not illuminate.
(6) Release PUSH TO TEST switch.
(7) Set COIL CURRENT control to extreme counterclockwise position.
(8) Set FUNCTION switch to OFF.
c. Coil Voltage Test (Delco-Remy 1115282).
See figure 2-5 and proceed as
follows:
(1)
Connect TEST LEAD with red boot to terminal lug on the end of the
wire to + connector.
(2)
Using adapter number 403BA034, connect the other TEST LEAD to the
connector.
Using adapter number 403BA033, connect COIL PICK-UP to coil secondary.
(3)
Be sure that adapter is firmly inserted into COIL PICK-UP and coil
secondary connector.
(4)
Connect the black lead attached to the COIL PICK-UP to the case of
the coil.
Set FUNCTION switch to COIL.
(5)
2-11
|