ASSEMBLY--Continued.
INSTALL COMPRESSOR HOUSING INLET AND OUTLET
ADAPTERS
TOOLS:
9/16 inch, 1/2 inch drive deep well socket
5/8 inch, 1/2 inch drive deep well socket
1/2 inch drive, O to 300 pound-inches torque wrench
NOTE
This procedure applies to "clean
air" turbosupercharger only.
INSTALLATION:
1. Install new preformed packings (A)
and (B) on compressor housing inlet
adapter (C) and outlet adapter (D).
NOTE
The inlet adapter is slightly
larger than the outlet adapter and
requires the larger preformed
packings.
2. Install adapters with preformed packings
in compressor housing (E).
3. Using deep well sockets arid torque
wrench, torque adapters to 60
pound-inches (6.8 N.m).
TA293557
3-28
Change 1