2950-01-048-8870">

 

Click here to make tpub.com your Home Page

Page Title: REMOVE PREFORMED PACKINGS, FILTER RETAINING STRAP AND FILTER FROM DUST DETECTOR COVER
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2990-206-34&P
DISASSEMBLY--Continued.
REMOVE PREFORMED PACKINGS, FILTER RETAINING STRAP
I
AND FILTER FROM DUST DETECTOR COVER
NOTE
This procedure applies to
"clean air" turbosuper-
charger only.
REMOVAL:
1. Remove filter retaining strap (A) and
filter (6).
2. Remove and discard three preformed
packings (C) from underside of dust
detector cover.
REMOVE COMPRESSOR COVER INLET AND OUTLET ADAPTERS
AND PREFORMED PACKINGS
TOOLS:
9/16 inch offset box wrench
5/8 inch offset box wrench
REMOVAL:
1. Using 5/8 inch box wrench, remove
compressor cover inlet adapter (A).
2. Using 9/16 inch box wrench, remove
compressor cover outlet adapter (B).
3. Remove and discard two preformed
packings (C).
TA293544
Change 1
3-10.1