TM 9- 2990- 205- 34&P
-
-
-
INSPECTION OF COMPONENT PARTS - CONTINUED
-
0010 00
10. Inspection of the Shield.
a. Inspect shield (1) for cracks or deformation.
b. Replace cracked shield.
1
03i483m
11. Inspection of Dust Detector Cover, Inlet and Outlet Adapters and Filter Retaining Strap.
NOTE
This procedure applies to "clean air" turbo only.
a. Inspect dust detector cover (1) for cracks, scoring of mating surface (2), and thread damage in tapped holes
(3).
b. Check adapters (4) and (5) for cracks, distortion, or thread damage. Ensure both are clear of obstruction.
c.
Inspect filter retaining straps (6) for cracks, bends, and general serviceability.
d. Verify presence of pipe plug (7).
e. Replace any of these components if damaged.
4
7
1
5
2
6
3
03i484m
END OF WORK PACKAGE
0010 00-108 0-ank
00-7/ 0bl-7
|