TM 9-2920-258-30&P
Preparation
a
1
Connect the test cable to the Alternator.
Make sure that all controls on the test stand are positioned as shown on Table 2-1 of TM 9-4910-
2
485-12.
3
Mount the direct drive Alternator to the low speed driving head.
4
Place the rectifier in the rectifier cooling chamber of the test stand.
5
Connect the cables and leads to the rectifier, regulator and binding posts of the side panel as
shown in Figure D-2.
Before starting the varidrive, place the test stand switches and selectors in the following positions:
6
A Place the DC ammeter load and starter selector (1) in the 500A position.
B Set the DC ammeter field and battery charger selector (2) in the 30A position.
C Determine that the DC voltmeter range selector (5) is in the 50V position.
D Check to see that the DC voltmeter circuit selector (6) is in the RECT GEN position.
E Snap the field circuit switch (36) in the REGULATOR position.
F All load switches (34) in the OFF position.
G Determine that the ground polarity switch (33) is in the negative (-) position.
H Place the AC ammeter range selector (9) in the 400A position.
I Determine that the AC voltmeter range selector (11 ) is in the 50V position.
J Make sure the field current control (41) is fully counterclockwise.
K Ascertain that the battery selector (31) is in the OFF position.
D-4
|