TM 9-2920-257-30&P
CAUTION
Care must be used when placing stator shell (12) on blocks to prevent damage to
stator windings and shell studs.
(11.) Support stator shell (12) on blocks with the six phase leads (black wires) and the two field leads pointing up.
NOTE
Normal mounting position is between the 1st and 2nd drain holes starting from the
left. (Closer to middle hole.) As the stator shell studs come through the holes in
the front housing, allow the phase leads (black wires) and the field leads to come
through the large openings in the front housing.
(12.) Align front housing (18) with the position marks on the generator core into the stator shell.
(13.) Install nine new flanged locknuts on stator shell studs. Tighten locknuts to 18 in-lb torque.
(14.) Install six phase leads, two field leads, and six nuts on front housing.
NOTE
There are two connector assembly configurations, both procedures for installation
are the same.
(15.)
Install connector assembly from front of housing.
See page 3-26 step 11 for procedures to install
connector assembly.
Change 1 3-37
|