Page Title: Remove six flange nuts
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2920-257-30&P
(17.) Remove six flange nuts (24) from core and shaft (4) studs.
(18.) Use three 10-32 UNF x 2 inch long machine screw as jacks. Install screws in threaded holes of front rotor
(19) end plate. Pull front rotor from core by gradually working screws against core in sequence.
c. N1205/N1206 Generator Assembly Procedures.
(1.) Clean bearing's inside diameter surface of front housing (18).
NOTE
Retaining ring (22) has two flat surfaces.
(2.) Install retaining ring (22) in square groove towards front of the front housing.
(3.) Coat outer face of front bearing (21) with a thin coat of sealing compound (item 7, App D)
(4.) Using a arbor press (item 4, App D), press front bearing (21) into front housing (18) until bearing seats
against retaining ring (22).
(5.) Install retaining ring (23) in front housing (18) groove.
Change 1 3-35