TM 9- 2920- 224- 34&P
-
-
-
DISASSEMBLY OF THE GENERATOR ASSEMBLY - CONTINUED
-
0008 00
WARNING
Do not use a voltage greater than 220V, and use care
when testing insulation resistance. Bodily injury can result
from contact with test voltage.
NOTE
All or part of series winding will measure zero ohms on
Rx1 meter scale due to low resistance of this winding.
aj. Check for grounded field windings using insulation test circuit (110 or 220 V in series with 50--watt lamp).
Connect one lead of test circuit to bare metal of housing frame and touch other lead (in succession) to E
terminal, B terminal, shunt lead, and series tap. Defective insulation will light test lamp, and housing must be
replaced.
ak. Remove capacitor (40), capacitor assembly (38), and ground lead assembly (32) from filter housing (26) as
follows.
al. Remove two washer screws (41) securing large capacitor (40) to filter housing (26), and remove capacitor.
am. Remove two washer screws (41) securing dual capacitor assembly (38) to filter housing (26), and remove
capacitor.