TM9-2815-224-34&P
Blower Maintenance Instructions (Cont)
(7)
Install four screws (7) and washers (8) finger tight.
(8)
Install six screws (9) and retainers (10) finger tight.
Using blower alinement tool, install blower drive shaft (11) and spring (12).
(9)
(10)
Tighten four screws (7) to 40 to 45 lb-ft (54.2 to 61.0 N-m),
(11)
Tighten six screws (9) in 5 lb-ft increments uniformly until tightened to 30 to 35 lb-ft (41.7 to
47.5 N-m).
(12) Retighten four screws (7) to 40 to 45 Ib-ft (54.2 to 61.0 N-m).
NOTE
Blower shaft should move freely, if not, loosen screws and repeat steps (10), (11),
and (12).
(13) Remove blower alinement tool.
(14) Push in on blower drive shaft (11) and install retaining ring (13).
(15) Install two hoses (14) and tighten four clamps (15) on two crossover tubes (16).
(16) Install fuel control rods (17), on both sides of engine, with connecting pin (18) and connecting
pin (19).
(17) Connect fuel control rods (17) to injector control tube levers (20) with two clevis pins (21) and
cotter pins (22).
(18) Install wires (23) on buffer switch (24).
14-11
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |