TM 9-2815-224-34&P
Blower and Water Pump Drives Maintenance Instructions (Cont)
(2) Remove three screws (4), and two spring
plates (5) from auxiliary drive hub (6).
(3) Position blower drive support (7) in vise with soft jaws.
(4) Bend tangs of Iockwasher (8) away from nut (9).
(5) Remove nut (9), Iockwasher (8),
thrust washer (10), thrust
bearing (11), drive gear (12), and
second thrust bearing (13) from
blower drive support (7).
(6) Remove blower drive support (7)
from vise,
(7) Check inside diameter of two bushings (14). If diameter is more than
0.005 in. (0. 127 mm) larger than shaft diameter, replace bushings.
(8) Press two bushings (14) from drive gear (12).