Oil System Maintenance instructions (Cont)
(4) Remove gear (10) and shaft (7) from oil pump (3).
(5) Remove gear (11) and shaft (8) as
an assembly from pump (3).
(7) Remove two keys (12) from shafts (7 and 8).
b. Cleanig/lnspection.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
(1) Clean all metal parts with dry cleaning solvent.
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use
only with effective chip guarding and personal protective equipment
(goggles/shield, gloves, etc.).
(2) Dry parts with compressed air.
(3) Examine all parts for damage. Replace if damaged.
(4) Check for bushing diameters. Replace housing if bushing diameter is larger than 1.0056 inches
(25.542 mm).
8-15
|