(12) Remove plugs (21 and 22) from oil pan (3).
b. Installation.
WARNING
Adhesives, solvents, and sealing compounds can
burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or
death, keep away from open fire and use in
well-ventilated area. If adhesive, solvent, or
sealing compound gets on skin or clothing, wash
immediately with soap and water.
(1) Coat threads of plugs (1 and 2) with pipe
thread sealing compound.
(2) Install plugs (1 and 2) in oil pan (3).
(3) Coat threads of reducer bushing (4),
elbow (5), and drain plug (6) with pipe thread
sealing compound.
(4) Install reducer bushing (4), elbow (5) and
drain plug (6) in oil pan (3).
8-5
|