TM 9-2520-270-34
7. REMOVE DIRECTIONAL CONTROL
SLIDE (1), SPRING (2), AND
RETAINER (3).
8.
U S I N G RETAINING-RING PLIERS,
R E M O V E RETAINING RING (4).
DISCARD RETAINING RING.
9 . CHECK HOUSING (5).
10. CHECK HOUSING (5).
a.
Using small hole gage set and
a.
Using small hole gage set and
micrometer caliper set, measure
micrometer caliper set, measure
bore (6) in both ends of housing (5).
bore (7) in both ends of housing (5).
Do not measure threads.
Do not measure threads.
b.
If either measurement of bore (6) is
b.
If either measurement of bore (7) is
greater than 0.6256 inch (15.890 mm),
greater than 0.5006 inch (12.715 mm),
replace valve assembly and go to
replace valve assembly and go to
step 14.5. If not, go to step 10.
step 14.5. If not, go to step 11.
4-508
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |