Click here to make tpub.com your Home Page

Page Title: REMOVE PLUG
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2520-270-34
NOTE
Encased seal consists of a seal and two backup
rings.
4. REMOVE PLUG (1).
5. REMOVE ASSEMBLY (2)
a. Place assembly (2) in vise.
FROM VISE.
b. Thread slide hammer (3) into slide
a. Remove slide hammer (3) from slide
hammer adapter (4).
hammer adapter (4).
c. Pull out plug (1) from assembly (2).
b. Remove slide hammer adapter (4)
d. Remove encased seal (5) from plug (1)
from plug (1)
Discard seal.
6. REMOVE SETSCREW (6).
Push hydraulic accumulator piston (7)
a.
in and hold.
7. REMOVE PISTON (7).
Using 1/4-inch ratchet handle and
b.
a. Using plastic-faced hammer, tap
3/32-inch socket wrench attachment,
assembly (2) to remove piston (7).
turn setscrew (6) in until it goes
b. Remove and discard preformed
through wall of assembly (2).
packing (8) from piston (7).
Remove setscrew (6).
c.
GO TO NEXT PAGE
4-453
Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us