TM 9-2520-270-34
8. DISCONNECT HOSE ASSEMBLY (1)
FROM HYDRAULIC ACCUMULATOR (2).
a. Disconnect swivel nut (3) from
adapter (4).
9. REMOVE TWO LOOP CLAMPS (5).
a. Using wire-twister pliers, remove and
discard two Iockwires (6).
b. Using 3/8-inch drive ratchet handle and
5/32-inch socket wrench attachment,
remove bolt (7) screw, (8), and sleeve
spacer (9). Discard screw and bolt.
c. Spread open and pull off two clamps (5).
11. RELEASE HOSE ASSEMBLIES (1)
AND (14) FROM TRANSMISSION
HOUSING (15).
a. Using wire-twister pliers, remove and
discard Iockwire (16).
b. Using 3/8-inch drive ratchet handle,
6-inch extension, and 5/32-inch socket
10. DISCONNECT HOSE ASSEMBLY (10)
wrench attachment, remove screw (17),
FROM FIRST RANGE RELAY VALVE
clamp (18), sleeve spacer (19), and
ASSEMBLY (11).
second clamp (18). Discard screw.
a. Disconnect swivel nut (12) from
c. Release hose assemblies (1) and (14).
adapter (13).
GO TO NEXT PAGE
4-419
|