TM 9-2520-270-34
WARNING
Retaining ring is installed
under high tension. Use care
when removing and installing
retaining ring. Personnel can
be injured. Always wear
goggles.
CAUTION
Do not scratch carrier shaft when removing
retaining ring. Equipment can be damaged.
4. REMOVE TAPERED CONE AND
ROLLERS (4).
a. Using retaining-ring pliers, remove re-
taining ring (5) and thrust washer (6).
Discard thrust washer.
b. Remove cone and rollers (4).
5. INSPECT CONE AND ROLLERS (4).
a. Inspect cone and rollers (4) for damage.
See TM 9-214.
b. Replace cone and rollers (4) if
damaged.