TM 9-2520-270-34
WARNING
U s e care when removing
retaining ring. Retaining ring
can fly. Personnel can be
injured. Always wear goggles.
67. REMOVE RETAINING RING (1).
a. (H) Pry up cross shaft (2) through
controller opening (3).
b. Using retaining-ring pliers, remove
retaining ring (1).
70. INSTALL RETAINING RING (1).
a. (H) Reach in through controller opening
(3) and pry up cross shaft (2).
b. Using retaining-ring pliers, install
retaining ring (1).
C.
Go to step 66.
68. SELECT NEW SHIM (4) FROM CROSS
SHAFT SHIM KIT.
71. INSTALL LEFT-HAND OUTPUT HOUSING.
See task REPLACE LEFT-HAND OUTPUT
a. Using micrometer caliper set, select
HOUSING, page 4-314.
new shim (4) from shim kit that will give
a gap of 0.028-0.037 inch
72. INSTALL CONTROLLER ASSEMBLY. See
(0.71-0.94 mm).
task REPLACE CONTROLLER ASSEMBLY,
69. INSTALL NEW SHIM (4).
END OF TASK
4-235
|