TM 9-2520-270-34
WARNING
use care when removing
retaining ring. Personnel can
b e injured. Always wear
goggles.
48. REMOVE RETAINING RING (1)
AND SHIM (2).
a . (H) Reach in through controller
opening (3) and pry up cross
shaft (4).
b. Using retaining-ring pliers, remove
retaining ring (1).
c.
Remove shim (2).
49.SELECT NEW SHIM (2) FROM
SHIM KIT.
calipler set , select
a.Using micrometer
new shim (2) from shim kit that will
give a gap of 0.02B-0.037 inch
(0.71-0.1.94 mm).
50.
INSTALL
NEW
SHIM
(2).
5 1 . INSTALL RETAINING RING (1).
a. (H) Reach in through controller
opening (3) and pry up cross
shaft (4).
b. Using retaining-ring pliers, install
retaining ring (1)
c. Go to step 47.
52. INSTALL LEFT-HAND OUTPUT
HOUSING. See task REPLACE
LEFT-HAND OUTPUT HOUSING,
53. INSTALL CONTROLLER ASSEMBLY
See task REPLACE CONTROLLER
ASSEMBLY, page 3-32.
END OF TASK
4-182
|