TM 9-2520-270-34
WARNING
Solvent fumes can burn and
could poison you. Read warn-
ing in the front of this
manual.
2 4 . CLEAN GASKET MOUNTING
SURFACE (1) ON MAIN HOUSING (2).
a. Use wiping rag dampened with
cleaning solvent.
25. INSTALL NEW GASKET (3).
a . Apply petrolatum to gasket mounting
surface (1) on main housing (2).
b. Install new gasket (3) on main
housing (2).
27. REPAIRER AND HELPER, TURN
HOUSING ASSEMBLY (6) OVER.
28. INSTALL TWO EYEBOLTS (7) IN
THREADED HOLES (8).
26. INSTALL THRUST WASHER BEARING (4)
29. A T T A C H AND SECURE LIFTING
AND SPUR GEAR (5).
DEVICE (9) TO TWO EYEBOLTS (7).
4-176
|