TM 9-2520-270-34
7. REPAIRER AND HELPER REMOVE
SPUR GEAR (1) FROM HOUSING (2).
a. (H) Hold housing (2) on workbench.
b. Remove Iockwire (3) from six
screws (4).
c. Remove six screws (4) and washers (5)
Turn over housing (2).
d. Using pry bar, evenly pry off gear (1).
10. INSPECT BALL BEARING (6).
8.
REPLACE HOUSING (2).
a.
Inspect bearing (6) for damage. See
TM 9-214.
9.
RECORD FAILURE ON DA FORM 2407
b.
If bearing (6) is not damaged, go to
I
AND RETURN DEFECTIVE HOUSING (2)
step 11. If bearing is damaged, go to
TO DEPOT.
step 12.
4-84
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |