NOTE
There may be more than one washer. Retain all
washers for reinstallation.
2. REMOVE PLUG (1).
a. Using adapter and 5/16-inch socket
wrench attachment, remove plug (1).
b. Remove and discard preformed
packing (2).
c. Remove spring washer(s) (3).
3. REMOVE PRESSURE FLUID FILTER (4).
a. Using magnet, pull out filter (4) from
cavity (5).
WARNING
Solvent fumes can burn and
c o u l d poison you. Read
warning in the front of this
manual.
4. CLEAN FILTER (4).
a. Using cleaning solvent, clean filter (4).
5. INSPECT FILTER(4) FOR DAMAGE.
a. Inspect filter (4) for cuts, tears, or dents.
b. Replace filter (4) if damaged.