TM 9-2520-270-34
14. REMOVE TANG (2) FROM INSERT (3).
a. Place tang breakoff tool (4) in tapped
hole (5) with installed insert (3). See
task for proper breakoff tool.
13. REMOVE INSERTION TOOL (1).
b. Push down end of breakoff tool (4)
until tang (2) breaks off of insert (3).
a. Turn handle of insertion tool (1) to
the left until insertion tool can be
c. If tapped hole (5) is a blind hole,
removed.
remove and discard tang.
15. INSPECT INSTALLED INSERT (3).
a. Check that threads of insert (3)
are not twisted, cracked, or stripped.
b. Using depth gage, check that
insert (3) is at its correct depth
below surface. See task for correct
depth.
c. If new insert (3) was damaged during
installation, or installation depth is
not correct, go to step 1.
END OF TASK
2-170
|