TM 9-2520-238-34
REPAIR DIFFERENTIAL RIGHT ANGLE GEARBOX -- Continued
0028 00
NOTE
If inspection indicates that ball bearing requires replacement, do Step 18.
18. Remove ball bearing (1) from gearbox housing (2). Use a suitable bearing puller.
NOTE
If inspection indicates resilient mount requires replacement, do Step 19.
19. Remove resilient mount (3) from gearbox housing (2). Use remover and replacer (WP 0033 00, Item 21).
NOTE
If inspection indicates that eye bolt requires replacement, do Step 20.
20. Remove eye bolt (4) from gearbox housing (2). Discard eye bolt.
NOTE
If inspection indicates that pin(s) require replacement, do Step 21.
21. Remove pin(s) (5) from housing (2). Discard pins.
CLEANING
CLEAN, INSPECT, AND REPAIR
1.
Before inspection, repair, or assembly, clean all parts of each output shaft assembly. See WP 0014 00.
2.
Inspect all parts. Refer to (WP 0014 00) for general inspection and repair procedures. Check for minimum, maximum,
and important clearances of new or rebuilt parts and for wear limits to which a part may be worn before replacement is
required (page 0028 00-21).
0028 00-8
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |