Click here to make tpub.com your Home Page

Page Title: RUN-IN TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2520-238-34
REPAIR TRANSFER GEARCASE F -- Continued
0019 00
RUN-IN TEST
NOTE
Conduct run-in test in accordance with local standard procedures.
1.
Mount gearcase on test stand in the same position as when installed in the carrier.
2.
Fill gearcase with 5 pints of oil (WP 0014 00). Oil level is to be between the ADD and FULL marks on liquid level
gauge rod.
3.
Provide suitable external lubricating oil supply for the differential oil pump and the ramp hydraulic pump (if installed).
4.
Before run-in operation. Provide artificial heating and cooling, if needed.
NOTE
Do not allow oil temperature to exceed 280 degrees F (138 degrees C) at any time during run-in
tests. At each stage, watch for over-heating, undue noise, and vibration. Check all seals and
covers for oil leakage.
5.
Run gearcase in the following minimum time duration stages.
Table 1.
Stage (rpm)
Load (foot-pounds)
Stage Time (minutes)
1100 to 1300
No load
5
1900 to 2100
No load
5
2800 to 3000
No load
5
6.
Remove drain plug and drain oil for at least 15 minutes into a suitable container and then install drain plug.
7.
Leave oil residue in gearcase for rust prevention.
8.
Remove sling and lifting device from transfer gearcase.