TM 750-245-4
accidentally enter the adherent areas as a result of poor
c. Extrude potting material into an open mold by
workmanship.
placing the nozzle at the bottom of the mold and
retracting the nozzle as the cavity fills; keep the nozzle
c. While preparing adherent surfaces, consider
tip just below the level of compound in the mold. Be
which areas do or do not require adhesion. In potting,
sure to use access holes in closed molds, if they are
the mold or container becomes a part of the finished
provided.
product; therefore, adhesion to the mold is essential. In
embedding, however, a release agent must be applied
d. Before the potting compound solidifies, examine
to the mold before potting. Often, electrical wires with
any wires or other movable protrusions for alinement,
nonadherent surfaces are encountered. Do not attempt
and realine them as necessary.
to abrade or clean electrical wires or sleeved junctions
e. Special instructions or precautions which must
near the potted area, since the abrasion may cause
be observed while applying potting compounds covered
short circuits.
in (1) and (2) below:
d. Check each unit to be processed to insure that
(1) Staking sealants. Staking sealants are
components are in place and ready for potting or
noted for the controllability of their adhesive strengths to
encapsulating. Correct any discrepancies. Aline molds
metal substrates. These compounds remain liquid
and components in the fixtures and center all wires and
indefinitely until they are confined between closely fitting
components protruding from a mold uniformly in the
metal surfaces in the absence of air; then they change
cavity.
to an infusible, insoluble state. These compounds are
e. After the potting compound has cooled to room
used in sealing threaded fasteners, plugs, and threaded
temperature, proceed carefully to remove fixtures and
fittings against fluid pressure; in locking such threaded
molds, if required. Trim flash areas as required. Store
parts against working loose under shock vibration; and
fixtures and molds are required to keep them in good
in retaining existing or replacement ball bearings in worn
operating condition.
housings, thus eliminating the need for a press fit.
These compounds are supplied in color coded strengths
and two viscosities for each color. The metal substrate
9-15. Curing the Potting Compound
which the compound contacts is considered the catalyst.
a. Cure Conditions. All potting compounds require
(2) Urethane foams. Access holes in the
some curing period. The time required varies with the
mold should be no less than 1/2 inch in diameter, so that
heat applied. Observe the cure time and temperature
the mixed foam can be poured quickly into the part to be
specified by the instructions for each particular material.
potted. Bleeding vent holes should be provided if
The time and temperature of cure must be consistent
possible, and if not, the excess foam may exude from
with thermal limitations of the assembly to which the
the access hole when the foam rises. Make sure the
compound is applied to prevent damage to heat-
mold is heated according to the foaming instructions.
sensitive components or materials.
All foams are exothermic; the heat of reaction causes
b. Heat. To apply heat, use a forced-air-circulating
the chemicals to form gas pockets and cause foaming.
oven, if possible, capable of maintaining temperatures
If the heat from the reaction is used up in warming the
from 100 to 500 degrees F. within 3 10 degrees F.
mold, poor foaming action will result and the rise will be
When heat lamps are used, be careful not to develop
insufficient. A general rule, if mold-heating information
hot spots by concentrating heat in small areas. Rotate
is not provided, it to heat the mold from 100 to 120
the work on a turntable or by hand to prevent these hot
degrees F. for one hour just before foaming.
spots during heatlamp cure. Do not exceed curing
temperatures or the potting material, the potted part, or
9-14. Using Fixtures in Potting
both may be ruined.
a. Aline parts to be potted as instructed in the
c. Special Instructions. Special instructions or
technical documentation. Hold and aline the potted part
precautions which must be observed in the cure of
during the cure of the potting compound with fixtures
potting compounds are covered in (1) through (3) below:
such as molds, C clamps, spring clamps, weights,
(1) Silicones. A minimum of 20 percent
masking tapes, molded fixtures, or combinations of
relative humidity is necessary to cure silicone materials.
these devices in accordance with the specific
(Heat does not accelerate their cure.) Because of this
instructions.
moisture requirement, compounds applied thicker than
b. Release agents may be used on fixtures at
one-eighth inch require longer to cure than do thin
times, but avoid excessive use. Excessive release
coatings. As a general rule, for each one-eighth inch
agent can contaminate the operator's hands or can
thickness, allow 24 hours at room temperature for cure.
Post cure silicones for 15 to 60 minutes at 10 degrees
9-4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |