5-8.
TROUBLESHOOTING TABLE. If you observe an abnormal condition or result, refer to the troubleshooting table
below. Perform the checks and corrective actions indicated.
Table 5-1. Troubleshooting Procedures
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Power-on Indicator Lamp not illuminated.
Step 1. Check external power cable connections for good contact. Be sure the external power source is
on.
Tighten connections and/or turn external power source on.
Step 2. Check circuit breaker and power-on lamp.
Replace defective part(s).
Step 3. Check ON-OFF-POLARITY switch.
Replace defective part.
2.
Angle Position Indicator Power-on Lamp not illuminated.
Step 1. Check cables and connections to Angle Position Indicator and static power inverter.
Tighten connections.
Step 2. Check for output voltage from static power inverter, (115 Vac 400 Hz).
Replace defective component.
Step 3. Check the ON-OFF switch.
Replace defective component.