(2) The Gyro unit and Power Inverter cables are short cables terminating in the RMHS Reference Gyro Set Case to
respective units. The dc power input cables and angle position indicator cables are longer to accommodate the distance
to the external power source and ideal location of the angle position indicator.
1-9. PHYSICAL DATA
Directional Gyro CN-998B/ASN-43
height ............
5.94 inches
depth ............
7,56 inches
width ............
5.81 inches
weight ...........
6.0 pounds
Power Inverter PS-299-1
height ..........
5.5 inches
depth ...........
4.8 inches
width.............
7.0 inches
weight ..........
6.2 pounds
Angle Position Indicator Model 8300-02
height ...........
1.75 inches
depth ...........
12.0 inches
width ............
9.5 inches
weight ..........
4.0 pounds
1-10. PERFORMANCE DATA
Directional Gyro CN-998B/ASN-43
Magnetic heading has an accuracy of 1 degree
Slaving rate is 2.5 degrees 1 degree per minute
Power requirements are 115 Vac, 400 Hz; 30 VA starting and 20 VA running.
Power Inverter PS-299-1
Input voltage +20.0 to +29.0 Vdc
Operating temperatures -55 degrees C (-67 degrees F) to +55 degrees C (+131 degrees F)
Output voltage 115 Vac, 400 Hz, single phase, @ 150 VA
Angle Position Indicator MDL 8300-02
Accuracy to 0.03 degrees to 0.05 degrees
Resolution is 0.01 degrees
Input references from 47 Hz to 440 Hz
Input power 115/230 V RMs to 125/250 V RMs, 47 to 440 Hz; 25 VA max
1-8