NOTE
21. Replace tubing assembly (1).
Check shifting operation; cycle pump
NOTE
several times. If the air valve does not shift
properly, turn nut (9) down 1/2 turn;
Inspect tubing carefully for defective flares
recheck operation.
before installation.
19. Install shakeproof washer (8) and nut (7) on
22. Install into the circuit such as illustrated in
connecting rod (18). Hold nut (9) and tighten nut (7).
figure 2-1 and operate in accordance with operating
procedures outlined in Chapter 2.
20. Install gasket (6) and cover (5) and attach
with bolts (4).
SECTION III. TROUBLESHOOTING
4-4.
The following table lists possible problems
operation of the Hose Tester and suggests remedial
which may be encountered in the
action.
TABLE 4-1. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
REMEDY
No oil pressure
Low oil level in reservoir
Refill reservoir to sight
gage level (use oil con-
forming to MIL-H-5606
or MIL-H-82383)
Shop air supply interrupted
Check air source and
ensure 50 scfm at 100
psig
Air control valve
Open air control valve
(9, figure 2-1) partially closed
Air-operated pump (10) mal-
Refer to Paragraph 4-5
function
Low oil pressure
Air pressure regulator (3)
Reset air pressure reg-
not set correctly
ulator
Air pressure gage (7) mal-
Calibrate and adjust gage
function
Replace gage