TM 55-4940-353-13&P
furnished by the pump is monitored by two oil gages
hence the pump operation. The air pressure in this line
mounted on a manifold attached to the pump outlet port.
is adjusted by means of the air regulator. The other
One gage with a scale marked from 0 to 15000 psi in
valve is installed in the oil return line to the reservoir.
200 psi increments is used when high pressure testing is
This valve is closed during a test to pressurize the hose.
being performed. The other gage can be read in 50 psi
When the test is complete it is opened to allow the test
increments to 3000 psi. This gage is protected from
oil to return to the reservoir.
damage when high pressures exist in the manifold by a
gage saver adjusted to 2800 + 100 psig. A sight gage
1-8.
Adaptors. Sixteen adaptor fittings are furnished
installed in the oil return line allows the operator of the
with the Model 321 Hose Tester. These adaptors, which
Hose Tester to observe the return flow of oil to the
fit into the oil supply port of the gage manifold and the
reservoir.
oil return port on the oil control valve, enable the tester
to accommodate all hose assemblies MS28741-3
1-7.
Controls. Two needle valves control the
through MS28741-16 and MS28762-3 through
MS28762-16. Racks for storing the adaptors are
operation of the Hose Tester. One, installed in the line
integral parts of the tester.
to the air input port of the pump, controls that input and
SECTION III. TEST EQUIPMENT, SPECIAL TOOLS AND MATERIALS
MIL-H-5606 or MIL-H-82382o Clean ,SAE-10 oil or
1-9.
No special tools or test equipment are required
lighter grade should be used in the lubricator unit.
to operate or service the Model 321 Hose Tester. Test
oil must conform to
1-2
|