TM 55-4920-440-13&P
3-19. Floor Insert Fasteners and Plugs - Inspect
3-19
This task covers: Inspection of floor insert fasteners and plugs
INITIAL SETUP
Tools:
Personnel Required:
Key, socket head screw, 3/16", 5/32"
67W Aircraft Quality Control Supervisor
Flashlight
67Z Aircraft Maintenance Senior Sergeant
INSPECTION
NOTE
Go to step 2 if plugs are serviceable.
1. Inspect floor plugs.
a. Remove any floor plug (1) that will not screw
into floor insert (2).
b. Inspect plug (1) for damaged threads.
c. Install new plug (1) as required.
2. Inspect floor inserts when plugs are not damaged.
a. Visually inspect floor insert (2) with flashlight
(3).
b. If insert threads are damaged or insert has
broken loose in adhesive potting, replace. See TASK 3-
7.
END OF TASK
3-26
|