3-14. Fixtures - Water Feed Thru Connector - Replace (Cont)
3-14
4. Details for fabrication of new connector are in
5. Apply adhesive on side of collar (5) toward long
end of connector (3). (Use adhesive, item 1,
6. Install new connector (3) from outside of shelter;
long end of nipple thru hole.
7. Replace six screws (2), have helper install
washers and nuts (1), inside shelter, tighten
securely.
END OF TASK