TM 55-4920-440-13&P
WARNING
When all equipment and materiel is stored on the stationary side of the shelter, the limited
floor space presents a safety hazard to operating personnel. This is most critical during the
raising and lowering of the roof panel. Failure to observe supplemental instructions could
result in serious injury to personnel. Personnel inside the shelter could become trapped
between the roof panel and equipment bolted to the floor.
c. Two people inside the shelter, using the
support struts (1), will lower the roof panel (2) until two
personnel outside can reach and hold the weight of the
roof.
d. Inside personnel will shorten the struts (1) and
secure to roof brackets (3). They will then move into
position to assist outside personnel.
e. After all inside personnel are clear allow the roof
panel (2) to close to the vertical position.
f. After the shelter has been folded as 'detailed in steps a thru e and prepared in accordance with TM 10-5411-201-
14, the Production/Quality Control Shop is ready for transport or storage.
2-44
Change 1
|