Page Title: Repositioning ECUs in support frames.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-4920-440-13&P
2. Remove four screws (3) from top bar (4).
Remove three screws (5) from bottom bar (6). Stow in
wall locker.
3. Repeat steps1 and 2 with other ECU.
g. Repositioning ECUs in support frames.
WARNING
Four  people  are  needed  when
moving or lifting the Environmental
Control Units ( ECUs).
Each unit
weighs approximately 270 pounds.
Trying to move or lift an ECU
without sufficient help can cause
serious injury to personnel.
1.
Slide ECU (1) off end wall shelf (2).
2. Using lift handles (3) carry thru personnel
door (4) and Position in floor frame (5).
3. For shelter P/PN 136-0000-101) Slide
ECU (6) off side wall shelf (7). (For shelter P/N 5-4-
2828-1) Slide ECU (6) off end wallshelf (7A).
4. Using lift handles (3) carry thru cargo
door (8) and position in floor frame (5).
2-40 Change 1