4920-01-139-4534">
|
|
TM 55-4920-439-13&P
2-9. Power shutdown.
a. See that all electrical tools and shop equipment
have been turned OFF.
b. Circuit breaker panel. Move main circuit breaker
(1) in the circuit breaker panel (2) from ON to OFF.
c.
Disconnecting ECUs.
1. Place MODE SELECTOR switch (1) of ECU
(2) in OFF position.
2. Unscrew lock ring (3) and pull connector (4)
from ECU receptacle (5).
Store cable (6) IAW
TM 10-5411-201-14.
3.
Install cap (7) on receptacle (5).
d. Disconnecting power distribution panel from
e.
Disconnecting main power cable.
1. Ensure all circuit breakers on the power
distribution panel are in the off position.
1. Unscrew lock ring (1), disconnect power
cable connector (2) at power entry panel (3).
2. Disconnect color coded wires on pigtail from
lugs on generator.
2.
Install dust cap (4) on "P1" receptacle (5).
Change 1 2-21
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |