3-14. Fixtures - Water Feed Thru Connector - Replace (Cont)
3-14
5. Apply adhesive on side of collar (5) towards long end
of connector (3).
(Use adhesive, item 1, App D).
6. Install new connector (3) from outside of shelter; long
end of nipple thru hole.
7. Replace six screws (2), have helper install washers
and nuts (1), inside shelter, tighten securely.
END OF TASK