TM 55-4920-437-13&P
3-7. Insert Fasteners - Replace
3-7
This task covers: Replacement of insert fasteners
INITIAL SETUP
Personnel Required:
68D Aircraft Power Train Repairer
Reference Information:
TM 10-54-11-201-14
WARNING
Methylethylketone (MEK), used to clean replacement inserts, is flammable and
toxic. Use only in well ventilated areas. Breathing vapors can cause headaches
and nausea. Repeated contact with skin can cause irritation. If irritation persists
see a doctor. Contact with eyes, wash immediately with water for 15 minutes and
seek medical attention.
WARNING
Safety goggles shall be worn when drilling and cleaning holes for insert
replacement. Flying chips can cause eye injury or even blindness.
END OF TASK