TM 55-4920-433-13&P
2-9. Power shutdown.
a. See that all electrical tools and shop equipment
have been turned OFF.
b. Move main circuit breaker (1) in the circuit
breaker panel (2) from ON to OFF.
c. Disconnecting ECUs.
1. Place MODE SELECTOR switch (1) of
ECU (2) in OFF position.
2. Unscrew lock ring (3) and pull connector
(4) from ECU receptacle (5). Store cable (6) IAW TM
10-5411-201-14.
3. Replace cap (7) on receptacle (5).
1. Ensure all circuit breakers on the power
e. Disconnecting main power cable.
distribution panel are in the off position.
1.
Unscrew lock rings (1) disconnect power
2. Disconnect color coded wires on pigtail
cable connector (2) at power entry (3).
from lugs on generator.
Change 1 2-20
|