TM 55-4920-426-13&P
3-109
LOW PRESSURE FILTER -- REPLACE -- Continued
3-109
ASSEMBLY
a.
Position "O" ring on drain plug.
Install drain plug and tighten.
b.
Install lower gasket, lower plate and filter element.
c.
d.
Install middle gasket between middle and upper plates.
e.
Install "O" ring on plug.
f.
Install plug and tighten using 1- inch open end wrench. Keep upper plate from rotating while tighten-
ing plug.
Install upper gasket and cover.
g.
h.
Secure assembly with eight washers and nuts and tighten nuts.
i.
Service with hydraulic fluid, MIL-H-5606
Install access panel.
j.
END OF TASK
LOW PRESSURE FILTER TEST
3-110
3-110
Testing
This task covers:
INITIAL SETUP
Personnel Required
68H Aircraft Pneudraulic Repairman
TESTING
Operate test stand, refer to paragraphs 2-3 through 2-4j. Check for leaks.
END OF TASK